Heat-n-glo wall switch instructions

Jul 17, 2024
How often should you switch colognes? Find out how often you should switch colognes in this article. Advertisement Cologne is a great tool for polishing your look and making you sm....

1 Remote Controls, Wall Controls and Wall Switches. 2 Intellifire Plus™ Ignition System Wiring. 3 Intellifire Plus™ Ignition System. 4 Service Parts. Download this manual. Models: 6000C-IPI. 6000C-IPILP. 8000C-IPI.We have 1 Heat-N-Glo 6000TVB manual available for free PDF download: Installer's Manual . Heat-N-Glo 6000TVB Installer's Manual (16 pages) Brand: Heat-N-Glo | Category: Outdoor Fireplace | Size: 0.63 MB Table of Contents. Safety and Warning Information. 2. Table of Contents. 3. Service Parts Lists ...Replacement high temp limit switch / thermodisc with manual reset for Hearth & Home gas stoves and fireplaces. Click on the photo to enlarge and view other angles. Fits the following Heat N Glo gas fireplace models: ... Heat N Glo Gas Fireplaces: BV4236DBI; BV4842DBI; Heatilator part # SRV22922 Replaces old part number 22922BWall Switch Kit with battery backup ... Find architectural guides, 3D drawings, installation instructions and more in our pro tools center. Where to Buy. Connect with a Heat & Glo dealer near you to see the products firsthand or ask about specific pricing and details. Find a Dealer.I have a heat n glo sl-36gdv-cdn. My wall switch won't work. My pilot stays on and if I switch it to on underneath it lights up and my wall switch won't do anything. If. Turn it off underneath it turns off. I tested the thermopile and got 400mv on off and when I turned my wall switch no change and when I turned it on below I got like 175.Gas Heat n Glo Fireplace not igniting, Intermittent Pilot Ignition#1 issue and common issue is a failed ignition Module.Amazon Parts (Affiliated Links)https:...The Gas Supply Line. • At the gas line access hole the gap between the supply piping and gas access hole can be plugged with non- combustible insulation to prevent cold air infiltration. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08... Page 30: Step 8. Wiring The Fireplace.Security Code Check. 1. Move switch on the receiver to the "REMOTE" position (Fig. 2) 2. Push the "LEARN" button (an audible beep will be heard) NO audible beep is heard - Plug in receiver, verify 120v to the junction box (outlet) -Wait 2 minutes and try steps 1 and 2 again - If still no audible beep Action: Replace receiver. 3.The RC300 multifunctional remote control is designed to control pilot light, flame height, blower speed and up to two 120 VAC auxiliary functions on your gas fireplace. The RC300 is equipped with the thermostat functions which can automatically control the temperature in the room in which it is installed. The control is only for use with the ...The simple way to get rid of this issue is to resync the fireplace to recover the remote signals. You could resync the radio frequency signal following the steps below: Find the receiver box’s “LEARN” button. Press the button and release it. Press the fireplace remote’s “ON” or “MODE” button.The WSK300 multifunctional wall switch is designed to control fl ame height, blower speed, and up to 2 other 110-120 VAC auxiliary functions on your gas fi replace. Also, the wall switch is equipped with thermostat functions which can automatically control the temperature in the room in which it is installed. The control is only for useHeatilator & Heat N Glo Wall Switch Kit WSK-21-W, OEM. $ 39.00. Free Shipping On Orders over $75. *Includes Shipping On Parts and Accessory Orders in the Continental U.S. Only. Genuine OEM Wall Switch Kit for Heatilator, and Heat N Glo LP & NG Stove and Fireplace Models. Available by Special Order.Hearth & Home Technologies • FK-160C Fan Kit Instructions • 4016-200 • 21 1 tm Shock Risk Explosion Risk Do NOT wire 110-120 VAC to gas control valve. Do NOT wire 110-120 VAC to wall switch • Incorrect wiring will damage millivolt values. • Incorrect wiring will override IPI safety lockout and may cause explosion. WARNING IntroductionWSK-MLT MULTIFUNCTION WALL SWITCH - INSTALLATION AND OPERATING INSTRUCTIONS - Introduction The WSK-MLT multifunctional wall switch is designed to control fl ame height, blower speed, and auxiliary functions on your gas fireplace. For models equipped with the Intellifi re system (IPI), the cold climate function can control the pilot fl...This Owner's Manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals. The information contained in this Owner's Manual, unless noted otherwise, applies to all models and gas control systems. Your new Heat & Glo gas appliance will give you years ofHeat & Glo • GATEWAY • 288-900 Rev. AD • 3/13 1 Model: GATEWAY • DO NOT store or use gasoline or other fl am-mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance. - DO NOT touch any electrical switch. DO NOT use any phone in your building.1. the First Vent Component to the Starting Collars. Apply a 3/8 inch (9.5 mm) bead of stove cement around the 5 inch (127 mm) fireplace starting collar. Make sure that the fireplace rope gasket supplied with the fireplace seals between the first 8-5/8 inch (219 mm) vent component and the outer fireplace wrap.QuadraFire, Heatilator & Heat N Glo Wall Switch, OEM. $ 118.00. Free Shipping On Orders over $75. *Includes Shipping On Parts and Accessory Orders in the Continental U.S. Only. Genuine OEM Wall Switch for Quadra-Fire, Heatilator, and Heat N Glo LP & NG Stove Models. Guaranteed Best Price with the Fastest Shipping! 62 in stock.The simple way to get rid of this issue is to resync the fireplace to recover the remote signals. You could resync the radio frequency signal following the steps below: Find the receiver box's "LEARN" button. Press the button and release it. Press the fireplace remote's "ON" or "MODE" button.Push in plus rotate counter-clockwiseuntil and word "pilot" is in the 6 o'clock position.** Heat-N-Glo WSK-MLT Fireplace Trimmings also Remote Controls. ... turns the unit's ON/OFF swap (or wall switch or remote control) to the "ON" position to start your fire. ... *If your do not see ampere red or black ignition ignitor button, you do not have ...Why Heat & Glo . History & Heritage; Sustainability; Owner Support ... 3D drawings, installation instructions and more in our pro tools center. Where to Buy. Connect with a Heat & Glo dealer near you to see the products firsthand or ask about specific pricing and details. ... Electric Wall Mount Fireplace.Summary of Contents of user manual for Heat & Glo LifeStyle 6000 GDVFL. Page 1 Heat-N-Glo Fireplace Installers Guide Models: U.S. Patents 4,793,322; 4,875,464; 5,000,162 and Patents Pending 6000 GDVFL Canadian Patent 1,297,746 6000... Page 2 SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the ...This gas fireplace is designed to accept a 1/2 inch. (13 mm) gas supply line. To install the gas supply line: A listed (and Commonwealth of Massachusetts approved) 1/2 inch (13mm) tee-handle manual shut-off valve and a listed flexible gas connector are connected to the 1/2 inch (13mm) inlet of the control valve.The information contained in this owner’s manual, unless noted otherwise, applies to all models and gas control systems. Your new Heat & Glo gas fi replace will give you years of durable use and trouble-free enjoyment. Welcome to the Heat & Glo family of fi replace products! We recommend that you record the following pertinentWsk-mlt-glx multi function wall control by heat-n-gloSection 4: maintaining & servicing, maintaining and servicing your Glo heatParts assembly main fireplace glo bv heat gas oak. Glo xltHeat & glo fireplace 6000tr-oak user manual Heat & glo fireplace heat-n-glo fb-in user manualStep 9 finishing. Check DetailsThe information contained in this owner's manual, unless noted otherwise, applies to all models and gas control systems. Your new Heat & Glo gas fi replace will give you years of durable use and trouble-free enjoyment. Welcome to the Heat & Glo family of fi replace products! We recommend that you record the following pertinentView and Download Heat-N-Glo 6000TRXI installer's manual online. 6000TRXI indoor fireplace pdf manual download. ... SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully described in the Installing the Fireplace section of before starting the installation. ...1. the First Vent Component to the Starting Collars. Apply a 3/8 inch (9.5 mm) bead of stove cement around the 5 inch (127 mm) fireplace starting collar. Make sure that the fireplace rope gasket supplied with the fireplace seals between the first 8-5/8 inch (219 mm) vent component and the outer fireplace wrap.Page 76 B. Vent Components Diagrams (continued) Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed.Browse the Heatilator troubleshooting and FAQs section for answers to questions about our products, installation, service, maintenance, and more.The 6K/8K Series from Heat & Glo ... • Easy control with touchscreen remote, wireless wall switch or app • Heat Management puts the heat where you want it, when you want it ... Product installation must adhere strictly to instructions shipped with product. We recommend measuring individual units at installation. NOTE: Combustible material ...Typically, when using an electric fireplace as a heat source, homeowners tend to do so as supplemental heat. These units don't output nearly as much heat as other types of hearth: 5,000 BTUs per hour (on par with a standard space heater), versus anywhere from 10,000 to 60,000 for a gas or wood-burning fireplace.The Heat-N-Glo Warranty will be voided by, and Heat-N-Glo disclaims any responsibility for, the following actions: Ł Installation of any damaged fireplace or vent system component. Ł Modification of the fireplace or direct vent system. Ł Installation other than as instructed by Heat-N-Glo. Ł Improper positioning of the gas logs or the glass ...The 36" see-through gas fireplace delivers Heat & Glo quality in a myriad of styles to create a unique and inviting presence. ... Wall Switch Kit with battery backup ... Owner's Manual. See-Through/Pier. Service Parts. ST-DV36IN. Architect Guides. ST-DV36IN (HNG) ST-DV36IN (HTL)Hearth & Home Technologies • FK-160C Fan Kit Instructions • 4016-200 • 21 1 tm Shock Risk Explosion Risk Do NOT wire 110-120 VAC to gas control valve. Do NOT wire 110-120 VAC to wall switch • Incorrect wiring will damage millivolt values. • Incorrect wiring will override IPI safety lockout and may cause explosion. WARNING IntroductionFigure 6 Install the Wall Mount Figure 5 Install Batteries, Child Safety Switch, and Brand / Dealer Programming E. Wall Mount Installation (Optional) 1. Detach the IFT-RC400 from the wall mount. 2. Secure the wall mount on a flat wall surface using the two #6 screws and wall anchors provided. See Figure 6. 3. Place the IFT-RC400 inside the wall ...View and Download HEAT GLO SUPREME-I30-BIR installation manual online. SUPREME-I30-BIR indoor fireplace pdf manual download. Also for: Supreme-i30-ift, Supreme-i25-ift, Suprm-i30lp-ift, Supreme-i35-ift. ... DO NOT wire Appliance Size Left Side Right Side 110-120 VAC to the valve or to the appliance wall switch. 25 in. 10 ft. 6 in. 8 ft. Page 29 ...Preparing a fully cooked ham can be a delicious and convenient option for any occasion. Whether you’re hosting a family gathering or simply craving a flavorful meal, knowing how to...The information contained in this owner's manual, unless noted otherwise, applies to all models and gas control systems. Your new Heat & Glo gas fi replace will give you years of durable use and trouble-free enjoyment. Welcome to the Heat & Glo family of fi replace products! We recommend that you record the following pertinentIf you own a Heat N Glo fireplace or heating system, you know how important it is to keep it in good working condition. However, like any other appliance, issues can arise from tim...Outdoor Lifestyles y Hearth Home Technologies • Lanai 48/60 Installation Manual • 4111-901 Rev. I • 06/23 1 Installation Manual Installation and appliance setup INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. NOTICE: DO NOT discard this manual! Model: WARNING! Risk Of Fire!This manual is also suitable for: View and Download Heat-N-Glo 8000TVFL installer's manual online. Heat-N-Glo Fireplace. 8000TVFL indoor fireplace pdf manual download. Also for: 6000tvfl, Sl-36tv.Buy WSK-SOUL-TMR Heat N Glo Wall Timer Switch Part today at heatandgloparts.com. See a wide selection of Fireplace,Inserts and Stove repair parts like the WSK-SOUL-TMR in the online parts catalog. NONE 1 Sunday Apr 28, 2024 ASK AN EXPERT. BULK ORDER ...Heat & Glo, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044. Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo dealer, please call 1-888-427-3973.Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. F • 8/11 1 Models: ST-36TR-IPI ... - DO NOT try to light any appliance. - DO NOT touch any electrical switch. DO NOT use any phone in your building. - Immediately call your gas supplier from a neighbor's phone. Follow the gas suppli-er's instructions. ... DO NOT DISCARD THIS MANUALMulti-Functional Wall Switch Kit WSK-MLT For just the receiver see FP0666Cross ReferenceHeat-N-Glo: WSK-MLTHeatilator: WSK-MLTQuadrafire: WSK-MLTFireplace Models Click Manufacturer for Model Numbers Heat-N-Glo 6000TRXI-IPI 6000GLX-IPI Cerona 36" CERONA-36 CERONA-42 Cerona Gas Fireplace - Service Parts: Cerona-36 CeronaOnce the pilot is lit, continue to hold the valve knob in for 30 seconds, then slowly release. If the pilot light goes out, contact SUNDANCE Energy at (425) 414-8015 for service. Remember to shut the gas supply valve off (picture #1). If it remains lit, press the valve knob in slightly and rotate counter-clockwise until the word "ON" is in the ...Product Overview. Replacement 9 volt on / off wall switch kit (white) for Heat N Glogas log sets and inserts. Fits NG and LP units. Includes the switch, switch plate, wire, 9v battery and instructions. Click on the photo to enlarge and view other angles. Fits the following Heat N Glo Gas Fireplace models: OEM Hearth & Home part.• Install a switch lock or a wall/remote control with child protection lockout feature. • Keep remote controls out of reach of children. Figure 3.1 Clear Space Requirement - All Models Heat & Glo • SL-5, SL-7, SL-9 Owner’s Manual • 2392-981 Rev. J • 10/19... Page 8: General Operating PartsHeat N Glo. (1 review) Write a Review. $151.00. SKU: HTI-13-007. UPC: 652174360369. Availability: Usually Ships in 1 to 2 Business Days.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. Please contact your Heat-N-Glo Fireplace dealer for any questions or concerns. For the number of your nearest Heat-N-Glo dealer, 484-980-B 7/97.Proceed to Step 4. 4. If equipped with a fan, plug the fan cord into the power cord labeled “FAN”. Disconnect the two wires from the fan thermostat switch on the fi replace. Disconnect the two yellow wires from each other and connect them to the fan thermostat switch.Pauline. Slate. Steel Gray. Thala Beige. Powered Fans. Fan. Come home to the perfect fire. The 6K/8K Series gas fireplace combines the look and feel of a traditional fire with next-gen voice control and heat control.1 Remote Controls, Wall Controls and Wall Switches. 2 Lighting Instructions (Ipi) 3 Intellifi Re Ignition System. 4 Service Parts. Download this manual. See also: Owner's Manual. Model (s): CERONA-36. CERONA-42.Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. AC • 3/15. Pour demander un exemplaire en français de ce Manuel. du propriétaire, visitez www.heatnglo.com. Owner's Manual. Installation and Operation. • Leave this manual with. party responsible for use. and operation.1. Install the wall switch (provided in the kit) at a convenient location. This switch will control the HEAT - OUT fan. A variable speed type switch must NOT be used. 2. Wire 110 VAC service TO the wall switch and FROM the wall switch to the fan junction box. Use wire nuts to secure the 110VAC service wires to the hot and neutral fan wires and ...Furnace rollout switches are an important safety feature in heating systems. They are designed to monitor the temperature inside the furnace and prevent it from overheating. There ...This replacement wall switch fits many heat N Glo fireplaces. This is a genuine Heat N Glo fireplace replacement part that ships in new original packaging (it is not an after-market equivalent). Heatitalor Heat N Glo Part Number: HTI-12-007. Description: Replacement wall switch / keypad for Hearth & Home gas stoves and inserts.View and Download Heat & Glo 6000TRXI-IPI owner's manual online. Direct Vent Gas Fireplace Heater. ... Firestops are REQUIRED on both HEAT SHIELD sides of a combustible wall through which the vent passes. TRIM HEAT SHIELD IF TOO LONG, ADD TO NOTE: Model DVP-TRAP does not need an exterior SHIELD IF TOO firestop on an exterior combustible wall ...WSK-MLT MULTIFUNCTION WALL SWITCH - INSTALLATION AND OPERATING INSTRUCTIONS - Introduction The WSK-MLT multifunctional wall switch is designed to control fl ame height, blower speed, and auxiliary functions on your gas fireplace. For models equipped with the Intellifi re system (IPI), the cold climate function can control the pilot fl...Jan 18, 2024 · Wsk-mlt-glx multi function wall control by heat-n-gloSection 4: maintaining & servicing, maintaining and servicing your Glo heatParts assembly main fireplace glo bv heat gas oak. Glo xltHeat & glo fireplace 6000tr-oak user manual Heat & glo fireplace heat-n-glo fb-in user manualStep 9 finishing. Check DetailsWe have 1 Heat-N-Glo Gas Fireplace manual available for free PDF download: ... Lighting Instructions. 12. To Turn off. 15. Section 3: Maintaining and Servicing Your Fireplace ... Ipi Troubleshooting. 26. Optional Accessories. 28. Wall Switch. 28. Section 5: Your Fireplace’S Wiring. 28. Section 6: Replacement Parts and Accessories. 31 ...Dec 23, 2021 · 1. Heat N Glo Fan Not Working. The wires of your Hean N Glo fireplace are connected to a fan sensor switch. This switch will turn on the fan if your fireplace heats up to a certain temperature. It will also turn the fan off when you turn off the unit. The goal of the fan is not to circulate cool air into your room.Summary of Contents for Heat-N-Glo 6000TRS-AU. Page 1 THIS MANUAL MUST BE USED FOR INSTALLATION AND RETAINED BY HOMEOWNER FOR OPERATION AND MAINTENANCE. HEAT-N-GLO, a division of Hearth Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044, USA 1-888-427-3973 This product is covered by one or more of the following patents: (United ...

Did you know?

That View and Download Heat-N-Glo SL-950TR installer's manual online. SL-950TR indoor fireplace pdf manual download. Also for: Sl-750trs, Sl-550tr, Sl-550trs, Sl-750tr. ... Electrical wiring. Framing and finishing details. Whether optional accessories—devices such as a fan, wall switch, or remote control—are desired. Page 11: Section 3 ...Turn the fireplace on and off manually, or you can set the temperature for the room by turning on the thermostat setting and selecting the temperature you wish. The timer can be set in fifteen minute increments, up to 9 hours. Available countdown times are 15 min, 30 min, 45 min, and 1 hour to 9 hours (alternating every 30 mins.)

How Heat Glo • SL-7B Installation anual • 2395-980 Re i • 419 5 2 Getting Started A. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required.View and Download Heat-N-Glo SL-950TR installer's manual online. SL-950TR indoor fireplace pdf manual download. Also for: Sl-750trfl, Sl-750tr, Sl-550tr, Sl-750trs, Sl-550trs. ... PIGGYBACK CONNECTOR PIGTAIL BLACK S2 ON/OFF WHITE T2 SWITCH GAS VALVE RED T1 THERMOPILE BLACK S1 THERMOCOUPLE OPTIONAL WALL SWITCH, THERMOSTAT OR REMOTE Step 8 ...Page 28: Contact Information. Contact Information Heat & Glo, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www.fireplaces.com Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo dealer, please call 1-888-427-3973.View and Download Dyna-Glo GUH50NE/LE operating instructions and owner's manual online. ... Keep the vent connector runs as short as possible VENT TERMINATION ON SINGLE WALL VENT with a minimum number of elbows. ... IN. W.C. (KPA) supply back on. Turn up thermostat to call for heat. ALTITUDE FT. (M) When the main burners light using soapy water ...

When Mantel Shelves. Customize your fireplace with mantel shelving. Our exclusively designed shelving adds a distinctive touch to any fireplace in lengths and designs to accent any room. Fillmore 59". Non-Combustible Cove Gray 60". Non-Combustible Midnight Mist 60". Non-Combustible Tavern Brown 60". Non-Combustible Washed Cedar 60".1. Heat N Glo Fan Not Working. The wires of your Hean N Glo fireplace are connected to a fan sensor switch. This switch will turn on the fan if your fireplace heats up to a certain temperature. It will also turn the fan off when you turn off the unit. The goal of the fan is not to circulate cool air into your room.Method 2: Turning on Instructions (Standing Pilot): Now, it's time to learn how to turn on the Heat N Glo Fireplace with a standing pilot. Disconnect the fireplace from the electric power. Turn the gas control knob clockwise to set the knob to the Off position. Open the fixed glass assembly.…

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Heat-n-glo wall switch instructions. Possible cause: Not clear heat-n-glo wall switch instructions.

Other topics

fedex north hangar road

perigold promo code

dexcom g7 calibration Stove Heat & Glo VRT-BZ-N-AUB Owner's Manual. Freestanding stove (76 pages) ... GROUND Black Black White White Green Green JUNCTION BOX POWER SUPPLY WIRES SWITCH BOX Figure 7.4 Junction Box Wired to Wall Switch Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 R14 • 11/14... Page 31: Appliance Setup Refer to Figure 8.2 ... u spa napervilleredgifs his wank materials THIS MANUAL MUST BE USED FOR INSTALLATION AND RETAINED ... HEAT-N-GLO, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044, USA 1-888-427-3973 2022-900F 7/04 INSTALLATION AND OPERATION INSTRUCTIONS ... fan, wall switch, or remote control—are desired. did king von kill someonepeterbilt air conditioning diagramoz202 flight status 2 Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08 These units MUST use one of the vent systems described in the Installing the Fireplace section of theInstallers Guide.NO OTHER vent systems or components MAY BE USED. This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be ...There are several steps you can follow to fix the issue. To begin pairing your remote to your fireplace, first use the power button on the remote. Press and hold the power button for 10 seconds. Press and hold the red button until you hear two beeps. Then, use the remote to turn on or off your fireplace. statesville landmark obituaries Heat-n-glo wall switch. yank. Dec 15, 2007. Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment. We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.F. Black Glass Refractory Installation 6. Install top refractory panel. Rest it on top of the side glass panels and gently push to the rear. See Figure 6000CLX-IFT-G ,6000CLX-IFTLP-G, 8000CLX-IFT-G, 8000CLX-IFTLP-G 1. Install rear glass panel in front of insulation board on rear refractory bracket. teva 54 round whitesherry pollackmarlene benitez video View and Download Heat & Glo 36DV installer's manual online. Direct Vent Gas Fireplace Heater. 36DV indoor fireplace pdf manual download. Also for: Escape-36dv. ... (3V) OPTIONAL BATTERY BACK-UP ON/OFF WALL SWITCH VALVE LOW VOLTAGE SEE NOTE 1 REMOTE GROUND CONTROL NEUTRAL Back light must be wired to a separate 110-120 VAC wall switch. NOTE 1 ...To install the round baffle follow these steps: Tiara I Round and Square Baffle 1. Page 13 5.4m MAX. MAX. 5.4m Rise to Run Ratio = 1:1 NOTE: Optional Kit #970D can be used for this type of installation on model Tiara I-CE. TIARA II-CE VENTING WITH ONE 90 ELBOW MIN. 914mm MAX. 610mm MIN. 1.2m MAX. 1762mm MAX.