Ground wire size for 400 amp service

Jul 15, 2024
Size Strand* Breaking Strength Diameter Weight XLP 90˚C Poly XLP Poly 75˚C AWG/kcmil inches AWG/kcmil lbs inches lbs/kft lbs/kft amps amps AAC NEUTRAL MESSENGER - 8 Solid 0.045 8 7 310 0.49 94 93 55 45 ... ©2023 Priority Wire & Cable 10-2023 Quadruplex Service Drop Aluminum Conductor..

In the trough, the cables are tapped and feed into a 125 amp main breaker panelboard. This is a temporary service. The 400 amp disconnect feeds a double wide trailer, which is a temporary financial bank. the 125 amp panel feeds a work trailer. 500 mcm feeds the meter and the line side of 400 amp fused disconnect. The 500 mcm …A 200-amp panel using three 2/0 AWG, it is recommended to use a 2- or 2.5-inch conduit for easier pulling. #2. Voltage Drop And Why Length Matters. Voltage drop can be easily explained as the voltage is less at the end of a run than it is at the start. As wires get longer, the resistance increases causing the voltage to drop.1000 amp 1 phase parallel UG service from POCO pad transformer to CT meter. Parallel 400 MCM copper from meter to Wire trough. Landed in power buss and split to multiple ATS and a few 200 amp disconnects all outdoor, then fed to interior panels throughout. My confusion occurs with GEC size in 2017 NEC.Looking for advice from anyone who rebuilds services on the daily. In VA the status quo is a #6 cu from the disconnect, with two 8' ground rods for a 200amp . For a service (320 meter) that has two means of disconnect by way of 2-200 amp panels we generally will run to each ground rod unbroken and then through both disconnects.A few questions in regards to grounding a 400 amp commercial service with two 200 amp panels side by side being fed from one 400 amp meter. 1.) What article 250 table do I use in order to size the ground wire I need to use to bond water & gas pipes on a commercial building with a 400 amp...Jan 6, 2022 · Single Family Residential Electrical Services | NFPANote 2 under Table 250.66 makes it clear that if there are no service-entrance conductors present, “the grounding electrode conductor size shall be determined by the equivalent size of the largest service-entrance conductor required for the load to be served”. There are some grounding electrodes that are not sized from Table 250.66.Apr 18, 2023 · For the service wire, 150’ isn't quite far enough to have to worry about voltage drop. Service and feeder to a dwelling is entitled to a favorable derate at 83% of service size. So 400A x 0.83 = 332A. You need wire rated for at least 332A at 75C thermal. That works out to 600 kcmil aluminum. (340A).Application. Southwire® Type SE, Style SER service entrance cable is primarily used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard; however, the cable may be used in all applications where Type SE cable is permitted. SER may be used in wet or dry locations at temperatures not to ...Here is a list of the recommended ground wire sizes for different lengths of 50-amp circuits: Up to 100 feet: 6-gauge. Up to 200 feet: 6-gauge. Over 200 feet: 4-gauge. It is always recommended to use the largest possible ground wire that can fit in the conduit or electrical box. A larger ground wire provides a more reliable and safer electrical ...What is the minimum size of the copper grounding electrode conductor permitted to run to an 8 foot ground rod, to a 400 amp service installed with 500 kcmil copper? ... to be made from existing installations that do not have an equipment grounding conductor by installing an equipment ground wire from the new grounding-type receptacle to _____. ...GROUNDING (Refer to 500.01 Ameren Service Manual) All standard services that operate below 1000 volts as defined in Section 400 shall contain a grounded neutral conductor. A non-standard service that operates below 1000 volts as defined in Section 400 may have a grounded phase conductor used as a circuit conductor in the system.For the grounding electrode conductor size, using NEC table 250.102(C)(1) 4/0 Al requires #4 copper. 3/0 Al requires #6 To attach the grounding electrode conductor to the building foundation the building needs to be inspected prior to the foundation being pored to answer correctly.We would like to show you a description here but the site won’t allow us.what cable do I need for a 400 amp service 650 ft run and what transformer. On 2020-08-26 y Mike Lange . I am looking for underground wire size needed to run 1200 feet .. I would like a 30 amp 240 volt service . On 2020-08-20 by frank . what size underground wire do I use for 200 amp service for generator that is 200 ft away from the service meter?1000 amp 1 phase parallel UG service from POCO pad transformer to CT meter. Parallel 400 MCM copper from meter to Wire trough. Landed in power buss and split to multiple ATS and a few 200 amp disconnects all outdoor, then fed to interior panels throughout. My confusion occurs with GEC size in 2017 NEC.70 Amp Breaker Ground Service Wire Size Explained Portablepowerguides ... be separated structure tech inspections 125 installation cost residential aluminum needed for 200 quora ing tips of 400 advice conductor add pictures wikihow underground cable amps q chart 120 240 480v single 3 phase conduit do you use 100 hunker i run detached wired ...At the big 400 amperes current, the voltage drop is less significant. To help you out, we have prepared 2 charts for running a 0-500 feet wire for 400 amp service at 120V and 220V voltages. The 1st one accounts for a 3% allowable voltage drop, while the 2nd one accounts for a less rigorous 10% allowable voltage drop.The load site of meter panel feeds a 400 amp (fused) disconnect switch (again, located outdoors, parallel runs from the meter panel to the disconnect switch). All of this so far is installed. The meter panel and the disconnect switch are side-by-side. Next up is to install two outdoor 200 amp load centers (with main breakers) from the dual load ...Drive-by-wire technology has been around for some time, but how long before you drive your car with a joystick? Read about drive-by-wire in this article. Advertisement So there you...The wire -type equipment grounding conductor shall be sized in accordance with 250.122, based on the overcurrent protective device for the feeder or branch circuit. Wire -type equipment grounding conductors installed in cable trays shall meet the minimum requirements of 392.10 (B) (1) (c). Metal raceways or auxiliary gutters in accordance with ...GROUND (PER NEC) For 480 volt service, see drawing D9-5. For 277/480 volt service, ... 100 Amp 320 Amp 200 Amp SIZE METER 2" #4 #2 #6 2.5" * 4/0 3" 2/0 #4 ALUMINUM Current carrying & neutral wire size (per NEC) COPPER SIZE GROUND WIRE SIZE 350 500 #2 Notes: 1.The Customer is responsible for clearing and maintaining all right of way. 2.Location. California. Mar 23, 2008. #13. [email protected] said: I was turned down on a meter can for 400 amp service due to ground wire size. I have 400 amp service and I was rejected because of the ground from the meter can to the 8' grounding rod was a # 6, solid, bare ground wire with no splices. I think 250 .66 (a) applies.Without the 83% rule for dwellings, this would be 335A. For dwellings, it would be 400 (because we cant seem to go above 400 otherwise it would be 404). Because you have two service enclosures, see 250.64 (D) - depending on what method you use, there may be taps that can be smaller than the main GEC.Wire size (Aluminum) 50 Amps Grounded Ungrounded 2 # 8 # 8 1 # 10 Grounding 1 # 10 # 8 100 Amps Ungrounded 2 # 4 # 3 Grounded 1 # 6 # 4 Grounding 1 # 8 # 6 ... Note: Service equipment and service equipment grounding is not under the scope of the license for manufactured dwelling installers, limited installers, or limited skirting installers. ...Location. California. Mar 23, 2008. #13. [email protected] said: I was turned down on a meter can for 400 amp service due to ground wire size. I have 400 amp service and I was rejected because of the ground from the meter can to the 8' grounding rod was a # 6, solid, bare ground wire with no splices. I think 250 .66 (a) applies.Federal Specification A-A-59544. NFPA70: National Electrical Code. Specifications*: Insulated Conductor Size: 3/0. Bare Ground Size: 1/0 (19) Outside Diameter: 1.462 inches. Ampacity amps 225 @ 90°C. Net Weight: 2.129 lbs/ft. *Data provided on this page is subject to change based on different manufacturers variances.Apr 26, 2022. #4. Our poco would run a 4/0 triplex for a 400 amp underground service, until they got so many complaints about voltage drop. Apparently they got sued, now they reduced the max length of the secondary, and run 350. I built a 1200 amp service, and they wanted to drop 3-sets of 4/0 to it!If you have a 320 (400) amp meter base with 2 - 200 amp panels, one on each side usually, then a #2 copper is all you need, however if you are using a meter main panel then 1/0 copper is needed based on the notes to 250.66. Based on power company wire which is 350 kcm then a 1/0 is called for in 250.66 that is 1/0 aluminum. Hambone8780.For 200 amp panel that's 300 ft from the main service, you'll need to adjust the wire size for 266 amps (with the 83% standard considered). We got it with the following equation: 200 x 160% = 320A. 320A x 83% = 266A. Checking Table 310.16 again, that means you need at least to use 300 MCM copper or 400 MCM aluminum.October 9, 2023 by GEGCalculators. The size of the ground wire for an electrical circuit depends on the circuit’s amperage rating. Common ground wire sizes for copper conductors include 10 AWG for 20-50A circuits, 8 AWG for 60-100A circuits, and 6-4 AWG for larger circuits.Note 2 under Table 250.66 makes it clear that if there are no service-entrance conductors present, “the grounding electrode conductor size shall be determined by the equivalent size of the largest service-entrance conductor required for the load to be served”. There are some grounding electrodes that are not sized from Table 250.66.So what the AHJ is saying is you can run dual 250 kcmil aluminum feeders - so that means 6x 250 kcmil wires for two 200A feeders, plus 1 safety ground wire that can be shared. This scenario calls for you ripping out and selling your 500/300 kcmil wire. The AHJ is not authorizing paralleling! You cannot merge the two 200A circuits onto the 500 ...Re: 600 amp service grounding electrode conductor sizing the GEC is sized using table 250.66 based on largest service entrance conductors. But, for sizing the GEC to a ground rod, then you use 250.66(A). See also 250.52(A)(5)(b). If you're using Concrete-encased electrode (UFER) then, GEC not required to be bigger than #4, 250.66(B).If you want to convert the entire 200 amp 277/480 volt, 3-phase service to 120/208 volt, 3-phase, you would need a minimum of a 225 kVA transformer. However, a 150 kVA transformer will likely suffice if the HVAC equipment is 480 volt. ... (208 volts x 1.732), rounded up to the next standard OCPD size). Therefore, having a 400 amp, 120/208 volt ...In your example at no time can a future contractor add load beyond 570 amps so in my opinion it really is a 570 amp feeder protected by a 600 amp breaker as allowed by 240.4 (B). Two key points. 1) 240.4 (B) does not increase the capacity of the conductors. 2) 240.4 (B) does not apply for feeders 801 amps and larger.Learn what size ground wire and conductor you need for 400 amp service panels. Find out the NEC codes, local building codes and professional tips for copper, aluminum, bare and water ground wires.For the service wire, 150’ isn't quite far enough to have to worry about voltage drop. Service and feeder to a dwelling is entitled to a favorable derate at 83% of service size. So 400A x 0.83 = 332A. You need wire rated for at least 332A at 75C thermal. That works out to 600 kcmil aluminum. (340A).Copper wire, THWN, building wire, hook up wire, conduit wire, bathtub wire, lighting wire, nylon copper wire, construction cable, etc... Features: Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II. Jacket: A tough, polyamide, Nylon outer covering per UL-1063 and UL-83. Standards:What Size Wire Is Needed For 400-Amp Service? You need an aluminum wire of 1000kcmil while copper wire of 600kcmil at 167 °F-194°F. 400 amp wire size. Wire: Temperature: ... 200 Amp Service Ground Wire Size; 150 Amp Service; 800 Amp Service ; Stellar Jackson. Recent Posts. link to Can You Run 120V And 480V In The …what cable do I need for a 400 amp service 650 ft run and what transformer. On 2020-08-26 y Mike Lange . I am looking for underground wire size needed to run 1200 feet .. I would like a 30 amp 240 volt service . On 2020-08-20 by frank . what size underground wire do I use for 200 amp service for generator that is 200 ft away from the service meter?For a 400 amp service with aluminum, aim for a 1,000 kcmil wire. And for the ground, a 1 AWG aluminum wire should do the trick. So here’s a quick recap for you: Copper: Go with 600 kcmil for the main wire and 3 AWG for the ground. Aluminum: Opt for 1,000 kcmil for the main wire and 1 AWG for the ground.You are correct that 600kcmil is the right size for using a single wire per leg for the service entrance, though -- this gives you 340A at 75°C, just enough to meet our 332A requirement. Furthermore, it is about $0.50/ft cheaper at the time of this writing than the parallel conductors, and also takes up slightly less conduit area, albeit not ...service conductors must be bonded in accordance with the National Electrical Code. • A water line shall not be the sole means of grounding. 10. When either lightning rods or telephone ground rods are within 6 feet of the service ground, they must be bonded together with #6 stranded copper wire with approved clamps. 11.Wire Strength and Material. You'll need to consider wire strength and material when determining whether to use 2/0 AWG copper wire or 4/0 AWG aluminum or copper-clad wire. According to the NEC, these are the correct wire sizes for a 200-amp service: Service Rating (Amps) Copper (AWG) Aluminum or Copper-Clad (AWG) 100. 4.%PDF-1.4 %âãÏÓ 6 0 obj > endobj xref 6 54 0000000016 00000 n 0000001633 00000 n 0000001745 00000 n 0000002378 00000 n 0000002940 00000 n 0000003541 00000 n 0000004123 00000 n 0000004157 00000 n 0000004201 00000 n 0000004245 00000 n 0000005968 00000 n 0000007346 00000 n 0000008261 00000 n 0000009172 00000 n 0000009380 00000 n 0000010664 00000 n 0000011379 00000 n 0000012078 00000 n ...Pull wire. FIGURE 4.02, RESIDENTIAL SERVICE LATERAL CONDUIT INSTALLATION UG SERVICE (URD) SERVICE SIZE: 400 AMP MAXIMUM: Changed: Maximum service size to 400 Amp. Removed: …or driveway. Removed: Illustration of non-standard meter location. FIGURE 4.03A, TRANSFORMER PAD DETAIL UG SERVICE 75 - 500 KVA 3 PHASE: Changed: Ground wire requirement.What sz of direct burial wire for 200 amp service, 200' away coming from on the ground transformer? On 2019-03-28 by (mod) - Paul MOre-detailed wire sizing help including run length and wire size increases are at SE CABLE & BRANCH CIRCUIT WIRE SIZES vs AMPS. On 2019-03-20 by Paul. Need to carry 100 amps 500 feet. What size under …The service neutral can do double duty and ground the second disconnect and remaining service equipment if you ground one of them (per 250.142). Note that if you're doing a full 400A service, you'll need a 1/0 copper to your water pipes -- takes a larger clamp than the typical #10-2 clamps.Jan 11, 2007. #2. In our area the power company is responsible for the power to the meter base and it is often much smaller than the service size would allow under the NEC. But the power company is responsible for it and if there are problems, it is there troubles, not ours. You can only get meter bases rated 325 amp, otherwise you have to have ...In the trough, the cables are tapped and feed into a 125 amp main breaker panelboard. This is a temporary service. The 400 amp disconnect feeds a double wide trailer, which is a temporary financial bank. the 125 amp panel feeds a work trailer. 500 mcm feeds the meter and the line side of 400 amp fused disconnect. The 500 mcm …Re: Ufer Grounding - Sizing Conductor I will take the liberty of speaking for Ryan - If I am wrong, I am sure he will let us know Ryan is very detail oriented, I believe he is pointing out the difference between .52 (electrodes) and .66 (size of grounding electrode conductors). It is so very important to remember to read the words that are there, and to remember which Section number, Part ...Jul 18, 2005 · Thanks for the information.The soil is red clay with plenty of iron in it so there shouldn't be a problem there.The local building code chart guide only goes to 200 amp.It doesn't specify ground rod size just a depth of at least 4' in the ground and using #4 copper for the ground wire.The circuit length to the rod and back is 20'.The typical ...Wire Strength and Material. You'll need to consider wire strength and material when determining whether to use 2/0 AWG copper wire or 4/0 AWG aluminum or copper-clad wire. According to the NEC, these are the correct wire sizes for a 200-amp service: Service Rating (Amps) Copper (AWG) Aluminum or Copper-Clad (AWG) 100. 4.Without the 83% rule for dwellings, this would be 335A. For dwellings, it would be 400 (because we cant seem to go above 400 otherwise it would be 404). Because you have two service enclosures, see 250.64 (D) - depending on what method you use, there may be taps that can be smaller than the main GEC.If the ground wire is exposed to possible damage, install wire in 1/2 inch PVC conduit and securely strap. If metallic ... required for a 400-Amp service. All conduits must be furnished by ... WIRE SIZE-RESIDENTIAL 2/0 OR 3/0 CU. 1 /0 NEUTRAL 4/0 AL. 2/0 NEUTRAL400 amp ground wire size chart. Sizing electrical wiringPanel sub amp subpanel 60 wiring diagram breaker circuit electrical square install main wire box breakers feed lug size through 20 amp (breaker, ground, service) wire size 12v, 120v, 220vWire size for 400 amp service. Ground wire size for 320 amp service400 amp ground wire size chart 400 ...Aug 12, 2021 · If you are installing a 400 amp service then you can use conductors based on the table in art. 310 Not sure but if I were doing a calc I would use the 83% for the 200 amp service for the house and 200 amps for the shop which means you could use a wire rated for 366 ampsBy understanding what size ground rod is needed for a 400 amp service, you can ensure that your home is safe and sound. Service Entrance 100amp To 200 Code Questions. Untitled. What Size Wire Is Best For A 100a Sub Panel At 275 Feet Quora. Section 3. 400 Amp Meter Base Combo Grounding Diy Home Improvement Forum. Cost To Replace Electrical Panel ...6. A ''residential service'' is a service supplying a single or multi-metered residential building. This document addresses services through 600 amp, single-phase for 120/240 V. For three-phase residential services or services larger than 600 amp, see Document 063928. Standard voltage for single metered residential building is 120/240 V.Revised the title. Revised minimum size support posts to 2 ½ inch. Replace Note 5 (external ground rods) with old Note 6. Added new Note 6: ground movement protection. 13 : Added that the pole shall be new when installed. Revised minimum size of support posts to 2 ½ inch. Addednew Note 2. Remove old Note 9 (external ground rods), dA 100amp service requires a minimum wire size of #1 AWG. Long cable runs would see an increase in wire size. Section 310-15 of the NEC is used to determine wire size, including ref...So, a 250 kcmil wire is ideal for 200 amp. The size depends on how far you run the wires from the sub-panels to the main panels. The wire has to be at least 2 AWG thick. However, it also depends on the cable length. If you run a wire 200 feet away from the main electrical panel, use a minimum of 1-gauge copper wire.Conduit size required for 100, 200, 400 amp service. 400 amp isn't what I'd be considering, but the guy from the power company said running two pair of 200 amp wires would be sufficient. Electrician said 4/0 aluminum 3-wire for the 200 amp service. Electrician said #2 aluminum 4-wire for 100 amp service to the garage.Sep 6, 2023 · Common electrical services include 100, 200, 300, and 400 amps. You need 1¼ inch conduit for 100 amps, 2 inches for 200 amps, 2.5 inches for 300 amps, and 3 inches for 400 amps. The size may differ based on the wire size and the number of wires to put inside the conduit. Multiple factors can affect the conduit size for these electrical ...Oct 28, 2008 · You are corresponding with Joseph - Your personal On-Line “Electrical Consultant”. *****Click here to view my profile*****. Ok the code states you don’t need anything larger then a #6 solid grounding wire to bond to (2) grounding rods. You will need to space these 6’ apart minimum. Now from that main panel, you will run a 4 conductor ...Jan 28, 2010 · I know that the required size of the grounding electrode for a typical 200 Amp service is a #4 solid copper. Now, we are planning on a 400 Amp service and I'm not sure what size PG&E will be running in the 3" PVC service lateral conduit but the length is approx. 300' so I'm assuming a pretty large set of service conductors.Mar 2, 2021 · If you turn to Section 250.122 in the 2020 NEC, you find information that has been helping electricians to size equipment grounding conductors (EGC) for longer than most electricians have been pulling wire. If you were on the job prior to 1996, you would have happened on this information in “250-95” in your Codebook, instead of 250.122.6 AWG = 26,240 cm × 1.49 = 39,097.6 cm. According to Table 8, a 4 AWG copper is required = 41,740 cm. The minimum size equipment grounding conductor for this 200-ampere feeder is a 4 AWG copper conductor. The answer is based on NEC-2008, Sections 250.122, Table 250.122, and Chapter 9, Table 8 (conductor properties).Jul 15, 2013. #1. When installing service above ground for a 350 amp (one 200 amp and one 150 amp main breaker panels) what size wire is allowed. This is a commercial location...not a dwelling. I will be using copper conductors. The reason I ask is because the standard around here with inspectors for 400 amp is to use 500 kcmil which is rated ...A minimum of 4-gauge wire and 1 1/4-inch conduit is required for 100-amp service. Buildings that have gas heat may not need any more than 100-amp service. The service size of a bui...

Did you know?

That Common electrical services include 100, 200, 300, and 400 amps. You need 1¼ inch conduit for 100 amps, 2 inches for 200 amps, 2.5 inches for 300 amps, and 3 inches for 400 amps. The size may differ based on the wire size and the number of wires to put inside the conduit. Multiple factors can affect the conduit size for these electrical ...5000. 700. 1200. 6000. 800. 1200. Note: View wire size charts from the list below. Maximum Allowable Ampacities for Conductors in Raceway, Cable or Earth (30°C) Maximum Allowable Ampacities for Conductors in Free Air (30°C) Maximum Allowable Ampacities for Conductors in Raceway, Cable or Earth (40°C) Maximum Allowable Ampacities for ...

How We would like to show you a description here but the site won’t allow us.For example, Home Inspection Insider recommends using a PVC conduit of at least 1.5 inches in schedule 40 or 80 for underground installations of a 200 amp wire cable. When running three wires within the same conduit, a larger size of 2 or 2.5 inches is recommended. Electricians often use 4/0 AWG aluminum wire for long distances to save money on ...Apr 26, 2022. #4. Our poco would run a 4/0 triplex for a 400 amp underground service, until they got so many complaints about voltage drop. Apparently they got sued, now they reduced the max length of the secondary, and run 350. I built a 1200 amp service, and they wanted to drop 3-sets of 4/0 to it!SIZE OF EQUIPMENT GROUNDING CONDUCTORS (EGC) for Grounding Raceway & Equipment; Rating or setting of Automatic Overcurrent Device (OCPD) in Circuit ahead of Equipment [i.e Circuit Breaker]. Not exceeding (Amps) ... 400 kcmil *Ref: Table 250-122 *See installation restrictions in Section 250-120. ...

When Sep 29, 2023 · The best wire size for a 400 amp service would be 1,000 kcmil aluminum wire or 600 kcmil copper wire. The wire size can change based on factors like the wire material, distance, voltage drop, temperature, and overhead and underground power lines.For 200-amp sub-panel In the case of underground service, a minimum of 1.5 inches of schedule 40 or 80 PVC conduit is required for copper wire or #4/0 AWG for aluminum and copper-clad wire. You will also require a 250 kcmil-gauge copper wire. Be sure to have the proper wire size of 200 amp.…

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Ground wire size for 400 amp service. Possible cause: Not clear ground wire size for 400 amp service.

Other topics

magistrate bexar county san antonio tx

browning light 12 serial numbers

weather underground norristown pa 400 amp service requires a wire size of 1,000 kcmil. What gauge wire is required for ground rod? The NEC code specifies that a solid copper wire used to connect to a ground rod must be at least either #6 or #8 gauge (depending on the size of your electrical service cable). #6 cable cable will always satisfy the sizing requirement, though in ... louisville trampoline parkwhat happened to maddie kirker Referring to Table 250.66, the minimum size wire-type common grounding electrode conductor would be 1/0 AWG copper or 3/0 AWG aluminum or copper-clad aluminum conductors. This common GEC conductor is installed from the grounding electrode to the vicinity of the wireway.What is the correct way to do a 400 amp service with 2 200amp panels? Or a 600 amp with 3 200amp main breaker panels? Do I need a gutter above the panel with taps, or can I run 3/0 from each panel to the whether head? What about grounding and bonding two or 3 main panels? The service in question is 3 phase. bonnerups obituariesrobeson county mugshotstgcofficial.github Amps = Watts/Volts. These formulas can be used to calculate the capacity and loads of individual circuits, as well as for the entire electrical service. For example, a 20-amp, 120-volt branch circuit has a total capacity of 2,400 watts (20 amps x 120 volts). Since the standard recommendation is for the load to total no more than 80 percent of ... bennington place apartments wichita Don't Oversize Your Wire. The supply to an entire property gets a very special 83% derate.For 400A that means 332A, though it is commonly referred to as "Class 320" (for 320A). Take a look at standard ampacity tables and you see 500 MCM for copper and 600 MCM for aluminum for 340A. (Checked another table - the one I linked doesn't have an in-between, but it appears 400 MCM copper would be fine ...What is the correct way to do a 400 amp service with 2 200amp panels? Or a 600 amp with 3 200amp main breaker panels? Do I need a gutter above the panel with taps, or can I run 3/0 from each panel to the whether head? What about grounding and bonding two or 3 main panels? The service in question is 3 phase. howling rabbits beerworks menuusc trojan care epo84 lumber morehead ky Nov 9, 2006 · "inspector has turned down my service with the explanation that the circular mill of the 3/0 copper must equal or exceed the same as 600 kcmil copper needed to supply the ampacity of the service". Table 310.15(B)(6) lists the conductor size for a 400A dwelling service and feeders as 400 kcm copper or 600 kcm aluminum.