Synthes rfna inventory

Jul 14, 2024
9. DePuy Synthes Validation Lab Questionnaire Results for Femoral Recon Nail System. 12/06/2017. Windchill Document #0000266807. 10. DePuy Synthes Shared ….

Inventory Control Form - Stainless Steel. View PDF. Inventory Control Form - Titanium. View PDF. Select all documents (2) Download Selected Items. -. DePuy Synthes 3.5 mm Periarticular Proximal Humerus Plates are indicated for fractures, fracture dislocations, osteotomies, and nonunions of the proximal humerus, particularly in osteopenic bone.The Angular Stable Locking System (ASLS) provides angular and axial stability for screws used in combination with an intramedullary nail in the fixation of fractures. Provides improved stiffness and decreased interfragmentary movement compared to conventional locking. 1-3. Product Specifications. How to Use This Product.Inventory Control Form 4.5, 5.5, 6.5, 7.5 mm Cannulated Compression Headless Screws (CCHS) Implants The screws are made of titanium alloy (TAV) 30 mm 35 mm 40 mm 45 mm 50 mm 55 mm 60 mm 65 mm 70 mm 75 mm 80 mm 85 mm 90 mm 95 mm 100 mm 105 mm 110 mm 115 mm 120 mm 125 mm 130 mm 30 mm 35 mm 40 mm 45 mm 50 mm 55 mm …Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Reamer/Irrigator/Aspirator (RIA) Patient Information: J5769-C 7/09 Inventory Control Form Reamer/Irrigator/Aspirator (RIA) RIA Tube Assembly 314.745S Minimum 360 mm length, sterile 314.746S Minimum 520 mm length, sterile ...Inventory Control Form Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada Please contact your sales consultant for items approved for sale in Canada. *2.4 mm Cortex Screws in lengths 42–60 mm are available in the 2.4/2.7 mm VA-LCP Forefoot/Midfoot Plating System.Follow this step-by-step guide to build your Synthes mod mini inventory: Open the preferred form. Use the toolbar to adjust the template to your preferences. Complete the form providing accurate details. Click on the signature field and add your electronic signature. Send the document for signature to other signers if needed.9. DePuy Synthes Validation Lab Questionnaire Results for Femoral Recon Nail System. 12/06/2017. Windchill Document #0000266807. 10. DePuy Synthes Shared Instrumentation TFNA-FRN A.7. 2/8/2018. Windchill Document #0000273347. 11. DePuy Synthes Design Verification Report – T115 FRNProtection Tube – Bending Resistance. 10/13/2017.Specialties Supported: Craniomaxillofacial (CMF), Foot & Ankle, Spine, Sports Medicine, Trauma & Extremities. Foot & Ankle, Spine, Sports Medicine, Trauma & ExtremitiesSynthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes “Import-ant ...SYNTHES GMBH RFNA/ 10MM/ 400MM/ STANDARD BEND/ STER; ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES: Back to Search Results: Model Number 04.233.040S: Device Problem Adverse Event Without Identified Device or Use Problem (2993) Patient Problem Bone Fracture(s) (1870) Event Date 01/01/2022:The DePuy Synthes physician locator service lists local practitioners who treat specific medical conditions with DePuy Synthes products. If you would like to be listed in the locator, simply fill out the form and submit this form to your DePuy Synthes sales consultant. Upon submission, your profile information may be viewed by potential patients.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2933-M 12/12 Inventory Control Form 4.5 mm, 6.5 mm, 7.0 mm and 7.3 mm Cannulated Screws 4.5 mm Cannulated Screws, partially threaded LENGTH LENGTH 214.520 20 mm 214.522 22 mm 214.524 …Complete Synthes Rafn Nail Inventory Control Form 2020-2023 view with USAGE Legal Forms. Easily fill out PDF blank, delete, and sign them. Storage or ... Tips on instructions to fill out, edit and sign Synthes rfna inventory control form …Inventory Control Form QIS AND 2.0 MM CANNULATED SCREW SYSTEM PLUS (CSS+) Head Height: 1.65 mm Washer and Head Construct Height: 1.44 mm Thread Length Short Thread: approx. 25% Total Length or 4 mm Long Thread: approx. 40% Total Length Thread Length Head Height Construct Height Length Washers Part Number 04.353.900.05 Washer For 2.0 Cann Screw ...Deslice la broca canulada entre la vaina de protección hística y la aguja guía, y proceda a perforar con ella hasta el tope de la vaina de protección. Retire la broca, la vaina de protección hística y la aguja guía. Nota: Se recomienda abrir el fémur con un motor a alta velo cidad o a mano con cuidado.4 Surgical Technique ®• TFN-ADVANCED Proximal Femoral Nailing System (TFNA) The AO Principles of Fracture Management 1. Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3rd ed. Berlin, Heidelberg New York: Springer 1991.DESIGN EVIDENCE References: 1. DePuy Synthes Trauma, TFNA Pre/Post Fatigue Sliding Data Analysis. July 14, 2015. MT15-273. 2. Galal S, Nagy M. Non-parallel screw fixation for femoral neck fractures in young adults. Journal of Clinical Orthopaedics and Trauma. 8 (2017) 220-224.DePuy Synthes MatrixRIB straight plates are indicated for the fixation, stabilization and reconstruction of: • Rib and sternum fractures, fusions, osteotomies, and/or resections, including spanning gaps and/or defects • Pectus Excavatum, Pectus Carinatum, and other chest wall deformities DePuy Synthes MatrixRIB sternal plates, 2.8 mm thickness,Needham analyst Laura Martin reiterates Magnite Inc (NASDAQ:MGNI) with a Buy and a $15 price target. Needham's clients sha... Needham analyst Laura Martin r...SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2210-I 10/12 Inventory Control Form 2.4 mm, 3.0 mm, 3.5 mm and 4.0 mm Cannulated Screws 2.4 mm Cannulated Screws Long Thread LENGTH LENGTH 211.810 10 mm 211.811 11 mm 211.812 12 mm 211.813 13 ...Instructions for Use Retrograde Femoral Nail Advanced ... Nails.Inventory Control Form Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada Please contact your sales consultant for items approved for sale in Canada. *2.4 mm Cortex Screws in lengths 42–60 mm are available in the 2.4/2.7 mm VA-LCP Forefoot/Midfoot Plating System.Inventory Control Form Variable Angle Locking Hand System Titanium 1.3 mm Titanium Locking Plates* 04.130.150 Straight Plate, 6 holes 04.130.151 Straight Plate, 12 holes 04.130.152 T-Plate, 3 holes head, 5 holes shaft 04.130.153 Y-Plate, 3 holes head, 5 holes shaft 04.130.154 Phalangeal Base Plate, 2 holes head, 5 holes shaftInventory Control Form Variable Angle Locking Hand System Titanium 1.3 mm Titanium Locking Plates* 04.130.150 Straight Plate, 6 holes 04.130.151 Straight Plate, 12 holes 04.130.152 T-Plate, 3 holes head, 5 holes shaft 04.130.153 Y-Plate, 3 holes head, 5 holes shaft 04.130.154 Phalangeal Base Plate, 2 holes head, 5 holes shaftof DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contactSynthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form 2.7 mm / 3.5 mm Variable Angle LCP Elbow System 02.107.002 2 holes, right 02.107.102 2 holes, left 2.7 mm / 3.5 mm Variable Angle LCP Proximal Olecranon Plates 02.107.202 2 holes ...Inventory ontrol orm 3 3 Miscellaneous Implants Instruments Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. 3.5LCPPROXTIBICF001 07/22 219.98 Washer, 7.0 mm 292.20 2.0 mm K-wire, 150 mm, …synthes.vo.llnwd.netDESIGN EVIDENCE References: 1. DePuy Synthes Trauma, TFNA Pre/Post Fatigue Sliding Data Analysis. July 14, 2015. MT15-273. 2. Galal S, Nagy M. Non-parallel screw fixation for femoral neck fractures in young adults. Journal of Clinical Orthopaedics and Trauma. 8 (2017) 220-224.02.226.010, 02.226.011, 02.226.012... View More. PRODUCT CODES. DESCRIPTION. DePuy Synthes Headless Compression screws are available in a range of sizes from 1-5-6.5 mm. They are self-drilling and self-tapping, allowing surgeons to control compression during fixation procedures. Get in Touch with a Sales Consultant.Inventory Control Form Large Fragment LCP™ System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. LCPLARGEFRAGICF001v2 07/22 2 *Also available LengthLength 212.215212.201 42 mm 212.216 44 mm 212. ...About This Product. The LCP™ Proximal Tibia Plates are indicated for fractures of the proximal tibia and treatment of nonunions, malunions, and osteopenic bone. They are available in the following options: 3.5 mm LCP Proximal Tibia Plate. 3.5 mm LCP Proximal Tibia Plate – Low Bend. 4.5 mm LCP Proximal Tibia Plate.The MAXFRAME™ System is a ring fixation system that can be customized by the surgeon to address the individual characteristics of each case and enables surgeons to construct circular frames for acute correction as well as gradual correction with computer assistance. 1,2 *. Product Specifications.TFN-ADVANCED™ Proximal Femoral Nailing System (TFNA) – Screw Only fi Surgical Technique 3 The AO Principles of Fracture Management 1. Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3rd ed. Berlin, Heidelberg New York: Springer 1991.The Large External Fixation System uses a modular construction to allow flexibility and a variety of forms of assembly to externally stabilize long bones, pelvic ring fractures, arthrodesis, and osteotomies. The system combines the Modular Knee Bridge and the Pelvic Frame. Product Specifications.of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contact9. DePuy Synthes Validation Lab Questionnaire Results for Femoral Recon Nail System. 12/06/2017. Windchill Document #0000266807. 10. DePuy Synthes Shared Instrumentation TFNA-FRN A.7. 2/8/2018. Windchill Document #0000273347. 11. DePuy Synthes Design Verification Report – T115 FRNProtection Tube – Bending Resistance. 10/13/2017.6 DePuy Synthes Titanium Cannulated Lateral Entry Femoral Recon Nail Surgical Technique Clinical Cases Case 1–Standard locking • 85-year-old female • Isolated femoral shaft fracture (AO 32-A1.2) For simple shaft fractures, two proximal and two distal ML locking screws are normally sufficient to stabilize the fracture.Inventory Control Form TFN-ADVANCED™ Proximal Femoral Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TFN-ADVANCEDTM System (TFNA), Long Nails, 9 mm distal diameter, sterile Right Part # Left Part # Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S 280 125°SE_793147 AC page 2 / 6 Instructions for Use Femoral Recon Nail, Greater Trochanter B 9 mm Right Left Length 04.033.958S 04.033.959S 280 04.033.960S 04.033.961S 300In today’s fast-paced business environment, effective inventory management is crucial for the success of any organization. One of the primary reasons why inventory management is es...Craniomaxillofacial Distraction (CMFD) System. The modular CMFD system offers a low-profile stable distraction construct without unintentional reversal combined with intraoperative flexibility and ease-of-use during application and removal. 1-3. Anti-reversal detent clip is contained within distractor body for a consistent, smooth profile that ...4 DePuy Synthes Femoral Neck System (FNS) Surgical Technique Indications, Contraindications, and Warnings Indications The Femoral Neck System (FNS) is indicated for femoral neck fractures, including basilar, transcervical, and subcapital fractures, in adults and adolescents (12-21) in which the growth plates have fused or will not be crossed.4 DePuy Synthes Flexible Reamers for Intramedullary Nails Surgical Technique Hand Reamers, 6.0 mm, 7.0 mm, 8.0 mm • For use in medullary canals with an isthmus smaller than 8.0 mm • Use hand reamers incrementally to widen the medullary canal to 8.0 mm, before using the front-cutting 8.5 mm medullary reamer head under powerManaging inventory efficiently is crucial for any business, regardless of its size or industry. It ensures that you have the right products in stock, minimizes stockouts and overst...LCP™ Ulna Osteotomy System (2.7 mm) 02.111.900, 02.111.900S, 02.111.901... The LCP™ Ulna Osteotomy System is a comprehensive system of plates allowing for ulnar shortening osteotomies. The system provides a low profile, angular stable fixation with a choice of two cut styles: transverse (90°) and oblique (45°).synthes.vo.llnwd.netThe number of homes available for sale is finally improving, providing some hope for buyers burned out by an extremely competitive market. By clicking "TRY IT", I agree to receive ...LCP™ Ulna Osteotomy System (2.7 mm) 02.111.900, 02.111.900S, 02.111.901... The LCP™ Ulna Osteotomy System is a comprehensive system of plates allowing for ulnar shortening osteotomies. The system provides a low profile, angular stable fixation with a choice of two cut styles: transverse (90°) and oblique (45°).by the AO and DePuy Synthes and belong still to sur - geons basic armatorium used for fracture treatment, revision surgery and correction osteotomies. Due to their fixed-angle shape, successful application needs planning, concise orientation in all planes (AP and lateral views, rotation) and preparation of the channel for the blade. IntroductionAbout This Product. The Hindfoot Arthrodesis Nail permits a proper hindfoot alignment due to features such as: · Distal and talar locking options. · A spiral blade. · Lateral bend · End caps for improved stability2,3. Get in Touch with a Sales Consultant.In any business, effective inventory management is crucial for success. It involves the process of overseeing and controlling the flow of goods from the moment they are acquired to...4. DePuy Synthes TF10816 RFNA MDR Indication Language. 07/03/2022. Windchill Document #0000317918 5. DePuy Synthes RFNA Nail Inlay Axial Pullout Design Verification Report. 08/20/2020. Windchill Document #0000293479 6. DePuy Synthes RFN-Advanced System Locking Attachment Washer Rationale. 09/30/2020. Windchill …Synthes Tfna Inventory 7434-9176 Form Apply a synthes tfna inventory 8664 template to doing choose download workflow more streamlined. Get Form. Show details Hide details How information works. Open form follow the ... What produces the synthes rfna inventory legally binding? ...Complete Synthes Rafn Bolt Inventory Control Form 2020-2023 get use US Legal Forms. Easily fill out PDF clear, edit, and sign them. Save or instantly send your ready documents.SE_793147 AC page 2 / 6 Instructions for Use Femoral Recon Nail, Greater Trochanter B 9 mm Right Left Length 04.033.958S 04.033.959S 280 04.033.960S 04.033.961S 300Inventory Control Form 4.5 mm VA LCPTM Curved Condylar Plate System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. SS/VALCPCC/ICF/V2 04/22 Page 1 of 2 To order (USA): 800-523-0322At the end of this video, you should be able to describe the steps for placing the RFN-Advanced Retrograde Femoral Nailing System. This content is intended for Health Care Professionals in the United States.The purpose of this study is to determine if the use of a rIMN with a 10° distal bend (Retrograde Femoral Nail– Advanced Periprosthetic Nail (RFNA PN); Depuy Synthes, Paoli, PA) results in improved sagittal alignment in the treatment of PPDFFs compared to fractures treated with nails with a distal bend of 5° We hypothesized that the RFNA PN …Inventory Control Form Terminal Cannulated Trochanteric Fixation Nail System SYNTHES (USA) To Order: (800) 5230322 Patient Information: SYNTHES (Canada) Ltd. To Order: (800) 6681119 Dates: Hospital:. ASLS together include an intramedullary nail form the principle of the Intramedullary.Inventory Control Form - Stainless Steel. View PDF. Inventory Control Form - Titanium. View PDF. Select all documents (2) Download Selected Items. -. DePuy Synthes 3.5 mm Periarticular Proximal Humerus Plates are indicated for fractures, fracture dislocations, osteotomies, and nonunions of the proximal humerus, particularly in osteopenic bone.Inventory Control Form 2.0 mm Quick Insertion Screw (QIS) and 2.0, 2.5, 3.0, 3.5, 4.0 mm Cannulated Compression Headless Screws (CCHS) Implants The screws are made of titanium alloy (TAV) 10 mm 12 mm 14 mm 16 mm 18 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 36 mm 38 mm 40 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 36 mm 38 mm 40 ...INVENTORY CONTROL FORM 2.4 mm LCP Distal Radius Plate System Implants (cont’d) 2.4 mm LCP Distal Radius L-Plates, 2 holes head SHAFT HOLES LENGTH 242.500 –90° 3 40 mm 242.501 –90° 4 49 mm 242.502 +90° 3 40 mm 242.503 +90° 4 49 mm 2.4 mm LCP Distal Radius L-Plates, 3 holes head SHAFT HOLES LENGTH 242.504 +90° 3 40 mmCompleting any kind of forms, including the synthes rfna inventory electronically seems like a pretty simple process at first glance. Nevertheless, taking into account the nature of digital files, different market-specific rules and compliances are often unintentionally overlooked or misinterpreted.2 DePuy Synthes 4.0 mm Cannulated Screws Surgical Technique 4.0 mm Cannulated Screws Cancellous thread profile Self-drilling, self-tapping flutes Reverse-cutting flutes 1.25 mm guide wire Spherical underside 5.1 mm diameter low-profile head with 2.5 mm hex drive 2.6 mm diameter shaftWooCommerce is a powerful e-commerce platform that enables businesses to create an online store and sell products or services. One of the key aspects of running a successful WooCom...Red fuming nitric acid (RFNA) is a storable oxidizer used as a rocket propellant.It consists of 84% nitric acid (H N O 3), 13% dinitrogen tetroxide (N 2 O 4) and 1–2% water. The color of red fuming nitric acid is due to the dinitrogen tetroxide, which breaks down partially to form nitrogen dioxide.The nitrogen dioxide dissolves until the liquid is saturated, and …

Did you know?

That 2.7 MM VA LCP™ CLAVICLE System. Product Codes: 02.112.610, 02.112.611, 02.112.612... View More. PRODUCT CODES. DESCRIPTION. Designed based on an analysis of clavicle CT scans to enhance plate-to-bone fit on a broad range of patients 1 and to treat lateral, shaft and medial fractures for small, medium and large clavicles.4 Surgical Technique ®• TFN-ADVANCED Proximal Femoral Nailing System (TFNA) The AO Principles of Fracture Management 1. Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3rd ed. Berlin, Heidelberg New York: Springer 1991.MultiLoc™ Humeral Nail. EXPERT™ Humeral Nailing System. Diameters Available. Short Nails - 8 mm & 9.5 mm; Long Nails - 7 m and 8.5 mm. 7, 9, 11 mm. Length Available. 160 mm (Short Nail);180-315 mm (Long Nails) 150 mm (Short Nail);190-320 mm (Long Nails) Radius of Curvature.

How The purpose of this study is to determine if the use of a rIMN with a 10° distal bend (Retrograde Femoral Nail– Advanced Periprosthetic Nail (RFNA PN); Depuy Synthes, Paoli, PA) results in improved sagittal alignment in the treatment of PPDFFs compared to fractures treated with nails with a distal bend of 5° We hypothesized that the RFNA PN …If taking stock of your insurance coverage – be it for your home, car or life –ranks even lower than doing taxes and getting root… By clicking "TRY IT", I agree to receive n...RIA 2 (Reamer Irrigator Aspirator) Surgical Technique DePuy Synthes 3 Indications The DePuy Synthes RIA 2 System is intended for use in adults and adolescents (12-21 years) • To clear the medullary canal of the bone marrow and debris • To effectively size the medullary canal for the acceptance of an intramedullary implant or prosthesisSynthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form 2.7 mm / 3.5 mm Variable Angle LCP Elbow System 02.107.002 2 holes, right 02.107.102 2 holes, left 2.7 mm / 3.5 mm Variable Angle LCP Proximal Olecranon Plates 02.107.202 2 holes ...

When Synthes (USA) 1690 Russell Road Paoli, Pennsylvania 19301 Re: K042377 Trade/Device Name: Synthes (USA) Low Profile Reconstruction Plates Regulation Number: 21 CFR 888.3030 Regulation Name: Single/multiple component metallic bone fixation appliances and accessories Regulatory Class: I1 Product Code: HRS Dated: August 31, …Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants P J3266-K 3/11 Inventory Control Form DHS/DCS & DHS/DCS One-Step Insertion plvllllpklgulpu. † NT NT 4 16 mm 212.106 20 mm 212.108 4 4.x NT NT 44 4 4 16 mm 4 18 mm 4 20 mm 4 22 mm 44 4 4mm 4 28 mm 4 30 mm 4 32 mm ...…

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Synthes rfna inventory. Possible cause: Not clear synthes rfna inventory.

Other topics

onlinewagestatements cracker barrel

avro stocktwits

travel advantage network myrtle beach Instructions for Use (IFU) Johnson & Johnson Institute. Reimbursement Resources. Investigator Initiated Studies. CA Compliance. ASR Recall. . The Advanced Nailing System is a portfolio of nails to treat various …The EMAX™ 2 Plus System is the ultimate high-powered, lightweight 1,2, small bone cutting system. Designed for surgeon comfort, this lightweight 1,2 device gives surgeons the flexibility 1,3,7, power, and low noise they need for long, complex neurosurgery and spinal procedures. MIDAS REX MR7 High-Speed Drill System (Medtronic) gregg giannotti wfan wifewindow blinds menards Product Specifications. How to Use This Product. About This Product. The TFN-ADVANCED Nailing System is a part of the Advanced Nailing System from DePuy …SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2210-I 10/12 Inventory Control Form 2.4 mm, 3.0 mm, 3.5 mm and 4.0 mm Cannulated Screws 2.4 mm Cannulated Screws Long Thread LENGTH LENGTH 211.810 10 mm 211.811 11 mm 211.812 12 mm 211.813 13 ... 636 angel number meaning twin flamejesus calling january 30insite.utmck.edu 3.5 mm VA LCP® Proximal Tibia Plate, Small Bend Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. 02.127.210 4 holes, 87 mm, right 02.127.211 4 holes, 87 mm, left 02.127.220 6 holes, 117 mm, right 02.127.221 6 holes, 117 mm, left 02.127.230 8 holes, 147 mm, right 02.127.231 8 holes, 147 mm, left 02.127.240 … santander payoff overnight address DESCRIPTION. LCP™ Proximal Tibia Plates merge conventional plating techniques with locking screw technology to enable surgeons to create a fixed-angle construct while using familiar plating techniques. They are available in 3.5- and 4.5-mm sizes to accommodate a variety of fractures. Product Specifications. How to Use This Product. does buc ee's have free airotc wellcare 2023adams cable pay bill Remove gross soil using a soft-bristled brush or soft, lint-free cloth. 2. Manually clean device for a minimum of two minutes in a freshly prepared neutral or mild alkaline detergent solution. Follow the detergent manufacturer’s instructions for the correct dilution, temperature, water quality and exposure time.